Eltek Rectiverter Integrated 2U 48VDC 6kVA 1ph CTOR0402.1

Place of Origin China
Brand Name Eltek
Certification CE SGS UL 60950-1
Model Number CTOR0402.1
Minimum Order Quantity 10
Price USD2500-5500
Packaging Details Original Packed by Carton
Delivery Time 1 week * depends on quantity
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 200sets/month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Model Rectiverter Integrated 2U, 48VDC 6kVA 1ph CTOR0402.1 Voltage (default) / (adjustable Range 230 VAC / 200-240 VAC
Frequency (inverter Mode – Default) 50 Hz (adaptive) Power Maximum (continuous / Overload <15s) 4800 W (6000 VA) / 8000 VA
Current Maximum (continuous / Overload <15s) 26 ARMS / 34,8 ARMS Current (maximum) Quick Trip (20ms) 128 A (6 X Nominal)
Hold Up (Voltage Dips) (before Switching To Battery) 5 Ms
High Light

Rectiverter Integrated 2U 48VDC

,

Rectiverter Integrated 2U 6kVA

You can tick the products you need and communicate with us in the message board.
Model Rectiverter Integrated 2U, 48VDC 6kVA 1ph CTOR0402.1
DC Output Voltage (default) / (adjustable range) 53,5 VDC / 43-58 VDC
Power (maximum @nominal input) 2400 W
Current (maximum @VOUT ≤ 108 VDC) 50 A
Current sharing (10 - 100% load) ±5 % of maximum current from 10 to 100 % load
Load breaker type DIN rail mounted, 18 mm and 27 mm wide (13 mm on request)
Protection Short circuit proof, Over voltage shutdown, Reversed polarity and Fuse
Storing temperature -40 - 85 °C
Isolation 3.0 kVAC – input to output 1.5 kVAC – input to earth 0.5 kVDC – output to earth
Dimensions WxHxD (mm) 482 x 380 x H mm [19 x 14.9 x H inch] Height (H): - 5U: 222 mm [8.8 inch] - 6U: 267 mm [10.5 inch] - 7U: 311 mm [12.3 inch] - 8U: 356 mm [14 inch]
Weight 5 kg
Leave a Message
Model Rectiverter Integrated 2U, 48VDC 6kVA 1ph CTOR0402.1
Product Description

Rectiverter Integrated 2U, 48VDC 6kVA 1ph CTOR0402.1​

  • The Rectiverter 2U 19” Integrated System can beused as a standalone system bulk AC & DC output sintelecom applications where a 230/115VACand 48 VDCbackup is needed.
  • The total output power for both AC and DCis limited to a total 8 kW. AC and DC output limits can be set according to the connected load, where the limitation for AC load is set to max 6kVAand for DC load to max 4,8 kW.
  • As additional options, the measuring and signaling can be widely extended with the I/O Monitor CAN node

Eltek Rectiverter Integrated 2U 48VDC 6kVA 1ph CTOR0402.1 0