xProduct Details
Brand | Eltek | Part Number | 241115.650 |
---|---|---|---|
Country Of Origin | China | ||
High Light | 241115.650 Eltek Flatpack2 Rectifier,48V1500W Eltek Flatpack2 Rectifier,Eltek Flatpack2 481500 HE SOLAR Rectifier |
You can tick the products you need and communicate with us in the message board.
Brand | Eltek | |
---|---|---|
Part number | 241115.650 | |
Country of Origin | China |
Product Description
Flatpack2 481500 HE SOLAR 48V1500W Rectifier 241115.650
- With the MPPT* algorithm ensuring close to 100% panel utilization and an efficiency up to 96.5%, the galvanic isolated solar charger sets new standards for renewable power in telecom.
- The combination of innovative design, efficiency and reliability makes the Flatpack2 HE SOLAR stand out.
Technical Specifications | |
Model | Flatpack2 48/1500 HE SOLAR |
Part number | 241115.650 |
INPUT DATA | |
Voltage | Nominal: 170 – 230 VDC Tolerances: 85-265 VDC |
Voltage (start-up) | 150 VDC |
Maximum current | 9.5 Arms maximum at nominal input and full load 10 Arms maximum at 85VDC and full load |
Protection | Varistors for transient protection / Fuse in both lines /Reverse polarity |
OUTPUT DATA | |
Voltage (default) | 53.5 VDC Float/Boost: 48 – 57,6 VDC For input voltages > 230VDC output stand by/test voltage is limited |
Maximum Output Power | 1500W,derating below 170V input 800W at 85V input |
Maximum current | 31,3 Amps at 48 VDC |
Static voltage regulation (10-100% load) | ±0.5% from 10 - 100% load and supplied power not limited by PV panels |
Dynamic voltage regulation | ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms |
Ripple | < 250 mVPP , 30 MHz bandwidth , < 2 mV rms psophometric |
Protection | Overvoltage shutdown, short circuit proof, high temperature, hot plug-in inrush current limiting , Fuse |
OTHER SPECIFICATIONS | |
Peak Efficiency | >96% at 30-80% load and 200VDC input |
Isolation | 3.0 KVAC – input and output 1.5 KVAC – input earth 0.5 KVDC – output earth |
Alarms (Red LED) | High and low temperature shutdown, Converter Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm at 43.5V, CAN bus failure |
Warnings (Yellow LED) | Low input voltage,Low temperature shutdown,Charger in power derate mode,Remote battery current limit activated,Input voltage out of range, flashing at overvoltage, Loss of CAN communication with control unit, stand alone mode |
Visual indications | Green LED: ON, no faults, Yellow LED : charger warning , Red LED: charger failure |
Operating temperature (5 - 95% RH non-cond.) | -40 - 75°C [-40 - 167°F ] |
Storage temperature | -40 to +85°C (-40 to +185°F) |
Cooling | Fan (front to back airflow) |
Fan Speed | Temperature and current regulated |
MTBF | > 350,000 hours Telcordia SR-332 Issue I, method III (a) (Tambient : 25°C) |
Acoustic Noise | < 20dBA at nominal input and full load (Tambient <= 25°C) < 56dBA at nominal input and full load (Tambient > 40°C) |
Humidity | Operating: 5% to 95% RH non-condensing , Storage: 0% to 99% RH non-condensing |
Dimensions | 109 x 41.5 x 327mm (W x H x D) (4.25 x 1.69 x 13”) |
Weight | 1.950 kg (4.3lbs) |
DESIGN STANDARDS | |
Electrical safety | IEC 60950-1 UL 60950-1 CSA 22.2 |
EMC | ETSI EN 300 386 V.1.3.2 EN 61000-6-1 (immunity, light industry) EN 61000-6-2 (immunity, industry) EN 61000-6-3 (emission, light industry) EN 61000-6-4 (emission, industry) |
Environment | ETSI EN 300 019-2-1 Class 1.2 ETSI EN 300 019-2-2 Class 2.3 ETSI EN 300 019-2-3 Class 3.2 ETSI EN 300 132-2 RoHS compliant |