Eltek Rectiverter 48V 241123.100 230V 1500VA 48V 1200W & 115V 750VA 48V 600W

Place of Origin China
Brand Name Eltek
Certification CE
Model Number 241123.100
Minimum Order Quantity 1
Price 320USD
Packaging Details Original Packed by Carton
Delivery Time 1 week
Payment Terms T/T
Supply Ability 200pcs/month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Brand Eltek Part Number 241123.100
Country Of Origin China
High Light

1500VA Eltek Rectiverter

,

48V Eltek Rectiverter

,

241123.100 Eltek Rectiverter

You can tick the products you need and communicate with us in the message board.
Brand Eltek
Part number 241123.100
Country of Origin China
Leave a Message
Brand Eltek
Product Description

Eltek Rectiverter 48V 241123.100 230V1500VA 48V1200W & 115V750VA 48V600W

 

Rectifier & Inverter in one box

  • Built on HE technology from the Flatpack2 HE rectifier family the Rectiverter 230/1500 48/1200 provides backed up power for 230 VAC loads with minimum losses and footprint.
  • It is a 3 port device capable of charging the 48V battery and simultaneously provides power for the AC and DC loads. During mains outage the Rectiverter feeds AC loads using energy stored in the battery.

 

 

Rectiverter 48V 241123.100 2301500 481200 & 115750 48600
Model 230/1500
48/1200
230/1500
48/150
230/1500
48/0
115/750
48/600
115/750
48/75
115/750
48/0
Part number 241123.100 241123.101 241123.102 241123.100L 241123.100L 241123.102L
INPUT DATA
Voltage range (nominal) 230 VAC / 200 - 240 VAC 115 VAC / 100 - 127 VAC
Frequency (default inverter mode) 50 Hz (adaptive) 60 Hz (adaptive)
Frequency (set-able inverter mode) 50Hz, 60Hz or last synced 50/60Hz (adaptive), 94-106Hz5), 74-76Hz
Power maximum (continuous / overload (<15s)) 1200 W (1500 VA) / 2000 VA 600 W (750 VA) / 1000 VA
Load sharing ±5% of active power from 10 to 100% load
Current maximum (continuous / overload (<15s)) 6.5 ARMS / 8.7 ARMS
Current (maximum) Quick trip (20ms) 32 A (6 x nominal)
THD < 1.5 % at resistive load
Protection Fuse in L, Hot pluggable, Varistor
OUTPUT DATA
Voltage (default) / (adjustable range) 53.5 VDC / 43 - 58 VDC
Power (maximum @nominal input) 1200 W 1) 150 W 0 W 2) 600 W 1) 75 W 0 W 2)
Current (maximum @VOUT ≤ 48 VDC) 25 A 1) 3.13 A - 2) 12.5 A 1) 1.56 A - 2)
Current sharing (10 - 100% load) ±5% of maximum current from 10 to 100% load
Static voltage regulation ±0.5% for 10 - 100% load
Dynamic voltage regulation ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms
Rippel < 200 mVPP , 30 MHz bandwidth
Protection Short circuit proof, Over voltage shutdown, Reversed polarity, Reversed polarity and Fuse
OTHER SPECIFICATIONS
AC Mains Input Voltage (range / LV disconnect) 185 - 275 VAC / 170 VAC 95 - 140 VAC / 85 VAC
AC Current (maximum) 11.5 ARMS 9.1 ARMS  8.2 ARMS  11.3 ARMS 10.1 ARMS  9.2 ARMS
Frequency (default: sync range) 47-53 & 57-63 Hz 47-53 & 57-63 Hz
Frequency (set-able: sync range) 47-53 Hz, 57-63 Hz or both (adaptive)
Power Factor / THD > 0.985 at 50% load or more / < 3.5%
AC Input Protection Fuse in L and N, Hot pluggable, Varistor
DC Voltage nominal / extended range4) 45 - 58 VDC / 40 - 45 VDC
DC Current (maximum) 32 A / 45A during overload (15s) 16 A / 22.5A during overload (15s)
OTHER SPECIFICATION
Efficiency >96% (mains mode), >94% (inverter mode) >92% (mains mode), >91% (inverter mode)
Isolation 3.6 kVDC - ACPorts to PE, 3 kVAC - ACPorts to DCPort/CAN, 710 VDC - DCPort to PE, 60 VDC - DCPort to CAN
Alarms: Red LED
Alarm relay [NO max 75 VDC / 100 mA]
(AC output OR DC output alarms)
Low and high mains input voltage shutdown, High and low temperature shutdown, Rectiverter Failure,
Overvoltage shutdown on output, Fan failure, Low output voltage alarm, CAN bus failure, Sync bus
lost and Sync fail
Warnings: Yellow LED Rectiverter in power de-rate mode or in power or current limit mode on DC or AC port, Remote output
current limit activated, Loss of CAN communication with controller
Normal operation: Green LED AC output and/or DC output on and ok
MTBF (Telcordia SR-332 Issue I method III (a)) 260 000 hours (@ Tambient : 25 °C)
Operating temperature  -40 to +75°C (-40 to +167°F), humidity 5 - 95% RH non-condensing
Temperature de-rating above 55°C (131°F) 1200W to 480W @ 75°C (167°F) for each, AC and DC, outputs (total power 2000W to 800W)
Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
Dimensions[WxHxD] / Weight 109 x 41.5 x 327mm (4.25 x 1.69 x 13”) / 1.95 kg (4.3 lbs)
DESIGN STANDARDS
Electrical safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, IEC/EN 62040-1:2008+A1:2013
UL 60950-1:2014, UL1778:2014, C22.2 No. 107.3-14
EMC EN 61000-6-1:2019, -6-2:2019, - 6-3:2007 + A1:2011, - 6-4:2019, IEC 61000-6-5:2015
EN 62040-2:2006, EN50121-4:2016+A1:2019, -5:2017+A1:2019
ETSI EN 300 386 V.2.1.1, FCC CFR 47 Part 15
Environment EU 2015/863 (RoHS) & 2012/19/EU (WEEE) / ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3)
Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per
IEC 62040-5-3:2016 clause 4.3, must be advised
     

 

 